3-Methylcrotonyl-CoA carboxylase deficiency detected by tandem mass spectrometry in mexican population.

Tandem mass spectrometry (MS/MS) was introduced to expand newborn screening in Nuevo Leon, Mexico. This has permitted an increase in the diagnosis of many metabolic disorders including isolated 3 methylcrotonyl CoA carboxylase deficiency (3 MCC). Detection of an elevation of C5OH by MS/MS is associ...

Full description

Bibliographic Details
Main Authors: Rangel Córdova, Enid Alda, Martínez de Villarreal, Laura Elia, Torres Sepúlveda, María del Rosario
Format: Article
Language:English
Published: Masson Doyma México, S.A 2009
Online Access:http://eprints.uanl.mx/8261/1/3MethylcrotonylCoA.pdf
_version_ 1824370670000144384
author Rangel Córdova, Enid Alda
Martínez de Villarreal, Laura Elia
Torres Sepúlveda, María del Rosario
author_facet Rangel Córdova, Enid Alda
Martínez de Villarreal, Laura Elia
Torres Sepúlveda, María del Rosario
author_sort Rangel Córdova, Enid Alda
collection Repositorio Institucional
description Tandem mass spectrometry (MS/MS) was introduced to expand newborn screening in Nuevo Leon, Mexico. This has permitted an increase in the diagnosis of many metabolic disorders including isolated 3 methylcrotonyl CoA carboxylase deficiency (3 MCC). Detection of an elevation of C5OH by MS/MS is associated with leucine catabolism disorders; false positive results are related with maternal transfer or immaturity of the enzymatic systems. The confirmatory diagnosis is based on organic acids test in urine and decreased enzyme activity in fibroblasts. We report three cases of abnormal C5OH in among 42 264 newborns (1:14000).1 The diagnosis was confirmed in only one child (~1:40 000). The incidence of 3 MCC deficiency in our state is similar to that of other populations. This is the first report about the incidence of this disorder in newborns in a Mexican population.
format Article
id eprints-8261
institution UANL
language English
publishDate 2009
publisher Masson Doyma México, S.A
record_format eprints
spelling eprints-82612023-05-10T15:17:53Z http://eprints.uanl.mx/8261/ 3-Methylcrotonyl-CoA carboxylase deficiency detected by tandem mass spectrometry in mexican population. Rangel Córdova, Enid Alda Martínez de Villarreal, Laura Elia Torres Sepúlveda, María del Rosario Tandem mass spectrometry (MS/MS) was introduced to expand newborn screening in Nuevo Leon, Mexico. This has permitted an increase in the diagnosis of many metabolic disorders including isolated 3 methylcrotonyl CoA carboxylase deficiency (3 MCC). Detection of an elevation of C5OH by MS/MS is associated with leucine catabolism disorders; false positive results are related with maternal transfer or immaturity of the enzymatic systems. The confirmatory diagnosis is based on organic acids test in urine and decreased enzyme activity in fibroblasts. We report three cases of abnormal C5OH in among 42 264 newborns (1:14000).1 The diagnosis was confirmed in only one child (~1:40 000). The incidence of 3 MCC deficiency in our state is similar to that of other populations. This is the first report about the incidence of this disorder in newborns in a Mexican population. Masson Doyma México, S.A 2009 Article PeerReviewed text en cc_by_nc_nd http://eprints.uanl.mx/8261/1/3MethylcrotonylCoA.pdf http://eprints.uanl.mx/8261/1.haspreviewThumbnailVersion/3MethylcrotonylCoA.pdf Rangel Córdova, Enid Alda y Martínez de Villarreal, Laura Elia y Torres Sepúlveda, María del Rosario (2009) 3-Methylcrotonyl-CoA carboxylase deficiency detected by tandem mass spectrometry in mexican population. Medicina Universitaria, 11 (45). pp. 238-242. ISSN 1665-5796 (Entregado)
spellingShingle Rangel Córdova, Enid Alda
Martínez de Villarreal, Laura Elia
Torres Sepúlveda, María del Rosario
3-Methylcrotonyl-CoA carboxylase deficiency detected by tandem mass spectrometry in mexican population.
thumbnail https://rediab.uanl.mx/themes/sandal5/images/online.png
title 3-Methylcrotonyl-CoA carboxylase deficiency detected by tandem mass spectrometry in mexican population.
title_full 3-Methylcrotonyl-CoA carboxylase deficiency detected by tandem mass spectrometry in mexican population.
title_fullStr 3-Methylcrotonyl-CoA carboxylase deficiency detected by tandem mass spectrometry in mexican population.
title_full_unstemmed 3-Methylcrotonyl-CoA carboxylase deficiency detected by tandem mass spectrometry in mexican population.
title_short 3-Methylcrotonyl-CoA carboxylase deficiency detected by tandem mass spectrometry in mexican population.
title_sort 3 methylcrotonyl coa carboxylase deficiency detected by tandem mass spectrometry in mexican population
url http://eprints.uanl.mx/8261/1/3MethylcrotonylCoA.pdf
work_keys_str_mv AT rangelcordovaenidalda 3methylcrotonylcoacarboxylasedeficiencydetectedbytandemmassspectrometryinmexicanpopulation
AT martinezdevillarreallauraelia 3methylcrotonylcoacarboxylasedeficiencydetectedbytandemmassspectrometryinmexicanpopulation
AT torressepulvedamariadelrosario 3methylcrotonylcoacarboxylasedeficiencydetectedbytandemmassspectrometryinmexicanpopulation